Gateways

CANable vs Actisense NGT-1 USB for OpenPlotter

Set up NMEA 2000 input in OpenPlotter with an Actisense NGT-1 USB or CANable. Identify the firmware path, verify Signal K data, and compare PGN controls.

Illustrated title card for the guide: CANable vs Actisense NGT-1 USB for OpenPlotter

For NMEA 2000 input in OpenPlotter, choose AUTO for the Actisense NGT-1-USB or MANUAL followed by slcand for a CANable running slcan firmware. A CANable running candleLight firmware appears as a native Linux SocketCAN interface. OpenPlotter USB setup · CANable firmware guide

Identify your gateway in software

Gateway or firmwareWhat Linux seesSoftware path
Actisense NGT-1-USBAn FTDI USB serial device when the driver recognizes it. CANboat gateway docsActisense serial gateway. OpenPlotter uses AUTO and lists it under CAN-USB. OpenPlotter USB setup
CANable with slcanA USB serial device, for example /dev/ttyACM0. CANable Linux guideChoose MANUAL in Serial, then use the slcand tab in CAN Bus. OpenPlotter USB setup · OpenPlotter slcand guide
CANable with candleLightA native SocketCAN interface such as can0, using the gs_usb driver. CANable firmware guide

The name can0 alone cannot identify the firmware. CANable also uses it as an example name for the interface created by slcand. CANable Linux guide

Add the input in OpenPlotter

Use these software steps with an existing NMEA 2000 installation. For physical installation, follow the maker’s manual and local rules. Actisense downloads and support · CANable documentation

Open CAN Bus from Main → OpenPlotter or run openplotter-can in a terminal. If the app is missing, install it from Settings. OpenPlotter CAN Bus app

Actisense NGT-1-USB

  1. In Serial, select the device, enter an alias, choose NMEA 2000 in the data field, and click Apply. OpenPlotter USB setup
  2. In Connections, select the device and click Add to CAN Bus. Set Baud Rate to the device’s rate, usually 115200, and click AUTO. OpenPlotter USB setup
  3. In CAN Bus, check that the device appears under CAN-USB. OpenPlotter USB setup

CANable with slcan firmware

  1. In Serial, select the device, enter an alias, choose NMEA 2000 in the data field, and click Apply. OpenPlotter USB setup
  2. In Connections, select the device and click Add to CAN Bus, then MANUAL. OpenPlotter USB setup
  3. In CAN Bus, open slcand and click Add device. Select the device you defined in Serial and click OK. OpenPlotter slcand guide
  4. Select the new entry and click Check device traffic to confirm reception. Then select the connection and click Add Connection. Signal K restarts. OpenPlotter slcand guide

Confirm live data in Signal K

  1. Open Server → Data Connections in the Signal K admin interface and confirm that the connection is present. Signal K configuration · OpenPlotter USB setup · OpenPlotter slcand guide
  2. Open Data → Data Browser and look for a value you expect from the NMEA 2000 network. Check its source and timestamp. Signal K Data Browser

What controls outgoing PGNs?

OpenPlotter pathGateway transmit control
Actisense NGT-1-USBOpenPlotter says most PGNs are blocked for transmission on the NGT-1. Open device TX PGNs controls which PGNs the device allows. OpenPlotter output guide
CANable via slcandOpenPlotter describes the slcand path as having no equivalent PGN transmit block. OpenPlotter output guide

On both paths, the Signal K to NMEA 2000 plugin controls which PGNs are converted from Signal K data. Once the plugin and conversion for a permitted PGN are enabled and the settings are submitted, a device already configured for input can start sending the converted data automatically. OpenPlotter output guide

If you already own an NGT-1 or need a replacement

Actisense lists the NGT-1 as retired and still provides drivers and manuals under Downloads & Support. Actisense NGT-1 support

If you’re comparing replacements, Actisense names the NGX-1 as the successor. The NGX-1 can operate as an NMEA 2000 PC interface. Actisense replacement notice · Actisense NGX-1

Evidence and limits

The input steps follow the OpenPlotter 4.x.x guides and Signal K configuration documentation, checked on 27 November 2026. This guide is not based on hands-on testing. Native SocketCAN coverage is limited to Linux interface identification. OpenPlotter USB setup · Signal K configuration

Sources

  1. Connecting a USB CAN converter - OpenPlotter 4.x.x
  2. Input data by slcand - OpenPlotter 4.x.x
  3. Output data - OpenPlotter 4.x.x
  4. Getting Started - CANable
  5. Gateways
  6. NGT-1 NMEA 2000 to USB and PC Interface | Actisense
  7. Configuration | Signal K
  8. CAN Bus - OpenPlotter 4.x.x
  9. NGX-1-USB NMEA 2000 to USB and PC Interface | Actisense

Related